Example
1)Expected life of equipment (required conditions)
A︓10 years with 24h operation
B︓10 years with 8h operation a day
2)Ambient temperature of capacitor
65℃ (Check ・ no heat generated part on reverse or around)
・Capacitor selection
case 1)
A︓For 10 years with 24h operation
L = 24(hour)× 365(day)× 10(year)
= 87600(hour)→ Working hours for 10 years
・Capacitor selection
case 1)
A︓For 10 years with 24h operation
L = 24(hour)× 365(day)× 10(year)
= 87600(hour)→ Working hours for 10 years
Because the value is larger than 32000 hours, the 105℃ 2000h product does not satisfy the expected life, and the ambient temperature should be lowed.
Case 2)
B︓For 10 years with 8h operation a day
B︓For 10 years with 8h operation a day
L = 8(hour)× 365(day)× 10(year)
= 29200(hour)→ Working hours for 10 years
Because the value is smaller than 32000 hours, the105℃ 2000h product can be used.